Individual Fire Symbols |
|
F034 - illuminated exit sign, dbl face |
|
F100 - extinguisher for all fires, except metal |
|
F035 - emerg. light, battery |
F068 - water mist exting-auto |
|
|
F036 - combined battery light & illuminated exit sign |
F069 - water mist exting-manual |
F102 - halon/clean agent extinguisher |
|
|
F070 - dry chemical sys - auto |
F103 - extinguisher/metal fires |
|
|
F071 - dry chemical - manual |
|
|
|
F072 - fires-all (exc metal) auto |
F105 - dry chemical reel station |
|
|
F073 - fires-all (exc metal) manual |
|
F008 - post-indicator valve |
F041 - water monitor alarm |
F074 - gasious medium - auto |
F107 - hose station, dry standpipe |
F009 - key operated valve |
|
F075 - gasious medium - manual |
F108 - hose station, charged standpipe |
|
|
F076 - halon/clean agent - auto |
|
|
F044 - abort switch (CO2) |
F077 - halon/clean agent - manual |
F110 - monitor hose, charged |
F012 - non-indicating valve |
F045 - line type detector |
F078 - fully sprinklered space |
F111 - purge controls, manual control |
|
|
F079 - partial sprinklered space |
|
F014 - backflow preventer-dbl |
F047 - smoke detector-duct |
F080 - nonsprinklered space |
|
F015 - backflow preventer-(RPZ) |
|
F081 - water spray system |
F114 - special spray nozzle |
F016 - pressure regulator valve |
|
|
|
F017 - pressure relief valve |
F050 - flow detector/switch |
|
|
|
F051 - pressure detector/switch |
F084 - upright sprinkler: nipple up |
|
|
F052 - level detector switch |
F085 - pendent sprinkler: drop nipple |
|
F020 - private hydrant, 1 outlet |
|
|
F119 - damper, fire/smoke |
F021 - public hydrant, 2 outlet |
F054 - valve w/tamper detector |
F087 - sidewall sprinkler |
F120 - damper, barometric |
F022 - public hydrant, 2 outlet |
|
|
F121 - pressurized stairwell |
F023 - wall hydrant, 2 outlet |
|
|
F122 - ventilation openings |
F024 - private hydrant, 2 outlet |
|
|
F123 - agent storage container |
F025 - fire dept. 2 outlet /freestand |
|
|
F124 - agent storage: carbon dioxide |
F026 - fire dept., 2 outlet |
|
|
|
F027 - fire dept. 1 outlet |
F060 - alarm, horn/light - 1 |
F093 - dry pipe valve w/quick open |
F126 - fusible link w/electrothermal |
F028 - fire pump with drives |
F061 - alarm, lamp/light-sep |
|
|
F029 - freestanding test header |
|
|
F128 - features (access, etc.) |
|
F063 - wet charge - manual |
F096 - Not Used |
F129 - detection/ extinguishers |
|
F064 - dry charged - auto |
F097 - water extinguisher |
|
|
F065 - dry charged - manual |
|
F131 - water flow control valve |
F033 - illuminated exit sign-single face |
|
F099 - extinguisher: liquid, gas, electrical |
|
|
|
|
|
|
|
|
F134 - Not Used |
|
|
|
|
|
|
|