MECHANICAL SYMBOLS LIBRARY
[Last Modification: 14 June 2005]



NOTE: Must have AutoCAD to open DWG files.
Individual Mechanical Symbols
M001 *FD-Floor Drain, *FS- Floor Sink, *RD-Roof Drain
M027 Globe Valve
M057 Expansion Loop
M087 Direction of Flow
M002 Pendent Sprinkler Head
M028 Globe Valve (angle)
M058 Flexible Pipe Connection
M088 Pitch Piping Down
M003 Sidewall Head
M029 Hose Bibb w/vac Breaker
M059 Pipe Anchor
M089 Mechanical Equipment Designation
M004 Upright Sprinkler Head
M030 Needle Valve
M060 Pressure Gauge with Valve
M090 Mechanical Equipment List
M005 Upright Sprinkler Head and Pendent Head Below
M031 Plug Valve Cock
M061 Steam Trap
M006 Alarm Valve
M032 Pressure Reducing Valve
M062 Strainer
M007 Dry-Pipe Valve
M033 Relief or Safety Valve
M063 Strainer w/blow-off Valve Strainer
M008 Deluge Valve
M034 Solenoid Valve
M064 Thermometer
M009 Pre-Action Valve
M035 Cap
M065 Test Plug (Press/Temp)
M010 Fire Department Connection
M036 Balancing Valve
M066 Temp Gauge with Valve
M011 Fire Department Connection Free Standing
M037 Not Used
M067 Meter
M012 Building Fire Control Panel
M038 Not Used
M068 Carbon Dioxide Suppression System
M013 Halon Control Panel
M039 Not Used
M069 Fire Protection Post Indicating Valve Number
M014 Fire Hydrant
M040 Not Used
M070 Block Valve Number-Fire Hydrant Number
M015 Post Indicator Vale
M041 Not Used
M071 Water System Block Valve Number
M016 EP, PE, SP, FS, FT, TT, PS, PT, TS
M042 Not Used
M072 Not Used
M016A Other Type of Switch more than two letters
M043 Not Used
M073 Key Box
M016B Other Type Switch (more then 2 letters with numerical tag)
M044 Not Used
M074 Cap or Plug
M017 T, H, HS, PS, TS
M045 Not Used
M075 Flexible Mechanical Coupling
M017A Other Type Sensor (more than two letters)
M046 Not Used
M076 Rigid Mechanical Coupling
M017B Other Type Sensor (more than 2 letters with numerical tag)
M047 Not Used
M077 Elbow-Turned Up
M018 Ball Valve
M048 Not Used
M078 Elbow-Turned Down
M019 Butterfly Valve
M049 Not Used
M079 Flange Connection
M020 Check Valve
M050 Automatic Air Vent
M080 Reducer -Concentric
M021 Control Valve (two way)
M051 Manual Air Vent
M081 Reducer-Eccentric-Bottom of Pipe Level
M022 Control Valve (3-way)
M052 Backflow Preventer
M082 Reducer- Eccentric- Top of Pipe Level
M023 Diaphram Valve
M053 Floor Cleanout
M083 Tee-Outlet Up
M024 Gate Valve
M054 Wall Clean Out
M084 Tee - Outlet Down
M025 Gate Valve (angle)
M055 End of Pipe Clean Out
M085 Union
M026 Gate Valve (OS & Y)
M056 Expansion Joint
M086 End of Pipe
End of Mechanical Symbols
Zipped files require WinZip for extraction.

 

Date SymNo. Reason for Revision
9/16/04 M020, M023, M031, M036, M072 Modified. M072 deleted.

To be notified of any changes to these documents, contact Tobin Oruch, Standards Manager.
Please feel free to send feedback/suggestions to the Discipline POC, Richard Trout

Operated by the Los Alamos National Security, LLC, for the U.S. Department of Energy's NNSA
Outside | © Copyright 2005–2006 LANSLLC All rights reserved | Disclaimer/Privacy | Web Contact