Individual P&ID and PFD Symbols |
|
P038 Not Used |
|
P152 - horiz. centrifugal pump |
|
P039 - instrument ID table |
P100 - ducted air flow from space |
P153 - centrifugal fan w/variable inlet vanes |
P001 - electromagnetic/sonic |
P040 - valve & instr. ID letters |
|
P154 - blower/centrifugal fan |
|
P041-49 Not Used |
|
|
|
P050 - Not Used |
P103 - gate valve - closed |
P156 - vertical wet pit pump |
|
|
P104 - globe valve - open |
P157 - progressive cavity pump |
|
|
P105 - globe valve - closed |
P158 - vertical sump pump |
P006 - electromagnetic/sonic |
|
P106 - needle valve - open |
|
P007 - internal system link |
|
P107 - needle valve - closed |
P159A - Not Used |
|
|
|
|
P009 - pneumatic binary signal |
|
P109 - plug valve - closed |
P161 - axial fan w/variable inlet vanes |
P009A - dashed2/electric binary |
|
|
P162 - 2-stage reciprocating air compressor |
P010 Not Used |
|
P111 - ball valve - closed |
P163 - single stage reciprocating air compressor |
P011 - Electrical Heat Tracing |
P059 - diaphragm actuator |
|
P164 - 2-stage rotary tooth air compressor |
P011A - cont/dash2-steam heat |
P060 - 2 way, fail closed |
P113 - spring check valve |
P165 - reciprocating pump |
P012 - discrete instrum./primary location/accessible |
|
P114 - angle valve - open |
P166 - pressure vessels, vertical or horizontal |
P013 - shared display./primary location/accessible |
P062 - 3 way, w/diaphragm |
P115 - angle valve - closed |
|
P014 - computer./primary location/accessible |
|
P116 - safety/relief valve (inlet port shown closed) |
P168 - HVAC coils (HW, DX, CH, STM, HCL, CCL) |
P015 - programmable logic./ primary location/accessible |
P064 - spring-opposed, single actuator |
P117 - 3-way valve (closed port darkened) |
P169 - unit heater (HW, DX, STM, HCL) |
P016 - discrete instr./ field mounted |
P065 - spring-opposed, double actuator |
P118 - 4-way valve (arrows indicate flow) |
|
P017 - shared display/ field mounted |
P066 - electrohydraulic actuator |
|
P171 - double containment tank |
P018 - computer / field mounted |
P067 - hand actuator or wheel |
|
|
P019 - programmatic logic/ field mounted |
P068 - restriction orifice |
|
P173 - manual balance damper |
P020 - discrete instr../primary location/accessible |
P069 - restriction orifice drilled in valve |
|
P174 - Not Used |
P021 - shared display./primary location/accessible |
P070 - flow straightening valve |
|
P175 - multi-point pitot tube array |
P022 - computer./primary location/accessible |
P071 - diaphragm pressure-balanced |
|
|
P023 - programmable logic /primary location/accessible |
P072 - pressure-reducing regulator-self contained/ adjustable set-point |
|
P177 - Not Used |
P024 - discrete instr../primary location/accessible |
P073 - pressure reducing regulator w/external pressure tap |
P126 - atmospheric filter |
P178 - evaporative air cooler |
P025 - shared display./primary location/accessible |
P074 - differential pressure regulator |
P127 - double basket strainer |
P179 - opposing blade damper |
P026 - computer./primary location/accessible |
P075 - back pressure regulator - self contained |
|
|
P027 - programmable logic ./primary location/ accessible |
P076 - back pressure requlator wi/external tap |
P129 - open drain (schematic) |
|
P028 - flow indicator for P016 |
P077 - pressure reducing regulator w/integral outlet pressure relief |
P130 - drain system annotations |
P182 - single duct variable volume box |
P029 - instruments common housing |
P078 - pressure indicator |
|
P183 - wing type face & bypass damper |
P030 - patchboard-point 12 |
|
P132 - cleanout (plan view) |
|
P031 - purge/reset/interlock |
P080 - pressure relief or safety valve |
|
|
P031A - signal directional |
P081 - vacuum relief valve |
|
P186 - fluid recovery pump |
P032 - S / D / P / T / M / SP |
P082 - pressure/safety valve, straight-through w/integral pilot |
P135 - space penetrations |
P187 - dual service heat exchanger |
|
P083 - rupture disk/safety head for vacuum relief |
|
P187A - single service heat exchanger |
|
P084 - rupture disk/safety head for pressure relief |
|
P188 - multi blade damper |
|
|
|
P189 - opposing blade damper |
|
P086 - flex connection (rubber) |
|
P190 - single blade damper |
|
|
|
|
|
P088 - single or venturi pitot tube |
|
|
|
|
|
|
|
|
P143 - flow control valve |
|
P032I - reverse proportional |
|
|
P195 - diaphragm lined tank |
|
|
P145 - automatic air vent |
|
|
|
|
|
|
|
|
P198 - carbon absorber filter |
P034 - piping class break or ML change |
P095 - flanged connection (piping or equip) |
P148 - Not Used |
|
P035 - pipe/wire continued, arrowpoint right |
P096 - flow orifice fixed |
P149 - Not Used |
|
P036 - pipe/wire continued, arrowpoint left |
P097 - strainer with valve |
|
|
P037 - pipe/wire continued, arrowpoint both |
|
|
|
|
End of P&ID and PFD Symbols |